Sign In | Join Free | My burrillandco.com
Home > Temperature Humidity Chamber >

Three Zone QT3 Thermal Shock Testing Chamber with Cascade Refrigeration System

    Buy cheap Three Zone QT3 Thermal Shock Testing Chamber with Cascade Refrigeration System from wholesalers
     
    Buy cheap Three Zone QT3 Thermal Shock Testing Chamber with Cascade Refrigeration System from wholesalers
    • Buy cheap Three Zone QT3 Thermal Shock Testing Chamber with Cascade Refrigeration System from wholesalers
    • Buy cheap Three Zone QT3 Thermal Shock Testing Chamber with Cascade Refrigeration System from wholesalers

    Three Zone QT3 Thermal Shock Testing Chamber with Cascade Refrigeration System

    Ask Lasest Price
    Brand Name : iqualitrol
    Model Number : QTS3-56A/B/C
    Certification :
    Price :
    Supply Ability : 5 Sets per Month
    Delivery Time : 30 Working Days
    Payment Terms : T/T
    • Product Details
    • Company Profile

    Three Zone QT3 Thermal Shock Testing Chamber with Cascade Refrigeration System


    Three Zone QT3 Thermal Shock Testing Chamber


    Brief Introduction:

    Q1-Test Thermal Shock Test Chamber QT3 Series is used to test products in alternating extremes of high and low temperatures in order to observe changes in product characteristics and failure occurrence,the applicable the object material, including metals, plastics, rubber, electronic, ..., etc., can be used as the basis of its product improvement or reference.

    QT3 series air-to-air thermal shock chambers circulate cold, hot, or ambient air as needed. The conditioned air is pre-cooled or pre-heated beyond the set point, allowing quicker recovery of the desired condition after transfer

    Features:
    1. Automatically setting of pro-cooled and pre-heated air.
    2. Testing samples don't move, cable port is available for power on testing.


    3. Powerful interactive touch screen controller, easy operation and setting
    4 .High accurate temperature recovery with PID auto tuning, High formula memory capacity can store 120 patterns, 9999 cycles, setting time for each pattern is 9999 Hrs 59 Mins


    5. Auto defrost function
    6. Three sections: High temperature zone, low temperature zone, testing zone.

    Testing Standards:
    MIL-STD-883E Method 1011.9 Thermal Shock
    MIL-STD-202G Method 107G thermal Shock
    JIS C 0025 Change of temperature
    IEC 61300-2-47 Tests-Thermal Shocks
    JESD22-A104C Temperature cycling
    GB/T 2423.22-2012 Test N: Change of temperature

    Chamber Dimensions:

    ModelInterior dimensions
    (W ×H × D)
    Interior VolumeExterior dimensions
    (W ×H × D)
    Specimen loading weight
    QTS3-56A/B/C400 ×350× 400mm
    15.7"×13.8"×15.7"
    56L1450× 1950 ×1600mm
    57.1" ×76.8" ×63.0"
    2.5Kg
    QTS3-80A/B/C500 ×400× 400mm
    19.7"×15.7"×15.7"
    80L1550× 2050 ×1600mm
    61.0" ×80.7" ×63.0"
    5.0Kg
    QTS3-150A/B/C600 ×500× 500mm
    23.6"×19.7"×19.7"
    150L1650× 2150 ×1800mm
    64.9" ×84.7" ×70.9"
    7.5Kg
    QTS3-225A/B/C750 ×600× 500mm
    29.5"×23.6"×19.7"
    225L1850× 2250 ×1800mm
    72.8" ×88.6" ×70.9"
    7.5Kg


    Technical Specifications:

    StructurePre-cooling Zone, Pre-heating Zone, Testing Zone (Selectable 2-Zone or 3-Zone Test for stationary object test)
    Damper DeviceForced Air Damper
    Test Cabinet TemperatureA= -35ºC~0ºC/60ºC~150ºC B= -55ºC~10ºC/60ºC~150ºC C= -65ºC~10ºC/60ºC~150ºC
    Interior MaterialSUS#304 Stainless Steel
    Exterior Materialstainless steel with environmentally baking paint
    Testing ShelvesStainless Steel Plate
    RefrigerationCascade Refrigeration System
    Cooling MethodWater/Air Cooling
    Ambient Temperature5ºC~30ºC
    Pre-heating Temperature80ºC~200ºC
    Pre-cooling Temperature-40ºC (-60ºC/-75ºC)~-10ºC
    High Temp. Shocking60ºC~150ºC
    Low Temp. ShockingA=―35ºC~0ºC
    B=―55ºC~10ºC
    C=―65ºC~10ºC
    Temp. UniformityLess than ±2ºC
    Transition time<10 seconds
    High Temp. Recovery timeRTºC~150ºC/5min
    Low Temp. Recovery timeRTºC~-75ºC/5min
    Pre-heating Time40min (30min for 56L)
    Pre-cooling Time80min (60min for 56L)
    ControllerPowerful interactive LCD touch screen controller
    Setting RangeTemperature: -200ºC~300ºC
    Time: 0H1m~9999H59m
    Cycle: 1~9999cycle
    ResolutionTemperature: 0.01ºC
    Time: 1min
    Control MethodPID+SSR
    Power supplyAC380V/50Hz/3P
    AccessoriesViewing Window, Cable Port, Chamber Illumination,
    LCD touch screen controller, Power cable
    Security SystemOverheat Protector, Compressor overload protector, Controller protector, Motor overload protector


    Note:
    1. Ambient temperature of +23ºC and a cooling water temperature of +25ºC
    2. During pre-heating, prevention for temperature heat-up may be worked
    3. Performance shown above conforms to IEC61300-2-47
    4. Temperature heat-up/pull-down time is applicable only during independent chamber operation.


    Quality Three Zone QT3 Thermal Shock Testing Chamber with Cascade Refrigeration System for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: DongGuan Q1-Test Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)