Sign In | Join Free | My burrillandco.com
Home > Temperature Humidity Chamber >

Multiple Sunlight Simulation Temperature and Humidity Test Chamber QYG-5000

    Buy cheap Multiple Sunlight Simulation Temperature and Humidity Test Chamber QYG-5000 from wholesalers
     
    Buy cheap Multiple Sunlight Simulation Temperature and Humidity Test Chamber QYG-5000 from wholesalers
    • Buy cheap Multiple Sunlight Simulation Temperature and Humidity Test Chamber QYG-5000 from wholesalers

    Multiple Sunlight Simulation Temperature and Humidity Test Chamber QYG-5000

    Ask Lasest Price
    Brand Name : iqualitrol
    Model Number : QYG-5000
    Certification :
    Price :
    Payment Terms : T/T
    Supply Ability : 5 Sets per month
    Delivery Time : 30 Working Days
    • Product Details
    • Company Profile

    Multiple Sunlight Simulation Temperature and Humidity Test Chamber QYG-5000


    Multiple Sunlight Simulation Temperature and Humidity Test Chamber QYG-5000


    Brief Introduction:

    The Q1-TEST Solar Simulation Test Chambers are state-of-the-art test units for simulating temperature and climatic indoor and outdoor conditions with global irradiation.


    The QYG-5000 simulates direct sunlight, heat, cold and humidity in order to test the many small and large items of day-to-day life that are subjected to different levels of solar radiation.


    These environments affect the service and operating conditions of various products exposed to these environmental extremes. They cause colors to fade and accelerate the ageing of materials.


    Technical Specifications:

    Name and modelSunlight Simulation Test Chamber QYG-5000
    Dimension and weight
    Internal Volume5600L
    Internal DimensionW1200mm×H1800mm×D2600mm
    External DimensionW1450mm×H2750mm×D3850mm
    Net weightAbout 1950kg
    Performance
    Test ConditionsAmbient temperature is 25℃, relative humidity ≤85%
    Under the condition that there are no samples in the test chamber
    Test MethodsGB/T 2423.2 Test B: High Temperature Test Method,
    GB/T 2423.3 Test Ca: Constant Damp Heat Test,
    GB/T 2423.24 Test Sa: Simulation of Solar Radiation on the Ground,
    GJB 150.3A High Temperature Test,
    GJB 150.9A Damp Heat Test,
    GJB 150.7A Solar Radiation Test (Test Curve), DIN 75220
    Temperature Range-20℃~+150℃
    Temperature fluctuation0.5℃(if by GB/T 5170.2, then indicates ±0.25℃)
    Temperature deviation±1.5℃
    Temperature uniformity

    1.0℃( Damp heat test ,humidity >90%RH)

    1.5℃(Temperature <100℃)

    2.0℃ No sunlight

    Light Parameters
    Light Illumination Wavelength and Test ConditionsFull-spectrum light DIN75220 and GJB150.17-86, simulating sunlight 280-3000nm
    Irradiation intensity(50–1500) ±10% W/m² (adjustable, minimum setting is 50 W/m², distance between light source and sample >0.76 m, distance adjustable), and can continuously record during the test, equipped with a lux meter
    Irradiation uniformityWithin 1㎡: 1000W/m2±100, 800W/ m2±80 W/m2
    Blackboard temperatureDisplay and configure 1 BST; (blackboard temperature is not controlled during high and low tests)
    Optical filter glassEquipped with DIN 75220 optical filter glass (removable)
    Lamp positionThe lamp tube is outside the equipment, at a distance of no less than 1.5 meters from the bottom of the equipment, located at the top.
    Temperature and Humidity Rise and Fall Requirements (No Light)
    Heating Time
    -20℃ →+120℃:≥2℃/min

    Cooling Time

    (Ambient Temperature 23~28℃)

    +120℃ →-20℃:≥1℃/min
    Humidity Range
    (Humidity range when the light is off)
    (10~98)%RH
    Relative humidity deviation

    ±2.0%RH(Humidity>75%RH)

    ±3.0%RH(Humidity≤75%RH)

    Work noise≤70dB(A)( Measured in a soundproof room with few echoes at an ambient temperature of 25°C; the average of 8 test points was taken; each test point is 1 meter horizontally from the noise source and 1 meter above the ground. )
    Structural Features
    Thermal insulation enclosure structureExterior wall material: double-sided galvanized steel sheet, surface sprayed with plastic (q1-test standard beige)
    Interior wall material: stainless steel sheet SUS304
    Cabinet insulation material: rigid polyurethane foam, fiberglass
    Door insulation material: fiberglass
    Air conditioning ductFans: 4
    Heater, evaporator (also dehumidifier), humidifier, overheat protector, water supply and drainage devices, dry bulb temperature sensor, wet bulb temperature sensor, wet bulb water pan
    DoorDouble-hinged door, left hinge, right handle (when facing the front of the cabinet door)
    Door equipped with an observation window and internal lighting
    Door frame equipped with an anti-condensation electric heating device
    Observation window1 transparent electric heating film anti-condensation insulated tempered glass window (located on the door)
    Visible area approximately: W350mm × H500mm
    Window frame is equipped with an anti-condensation electric heating device
    Test Ports2pcs, φ100mm, on left side of chamber
    Light1pc, 3W, High-efficiency long-life LED light source, located on the door
    Control panelController display screen, USB interface, RJ network interface
    Main power, over-temperature protection controller (right side)
    Standard Delivery
    ShelfAdjustable stainless steel sample rack, 1 tier, load capacity (evenly distributed): 50kg/tier
    (Total cumulative load of samples inside the box should not exceed: 100kg)
    CasterSix swivel caster wheels.
    Air conditioning system
    Heat transfer methodsAir circulation forced convection heat transfer
    Air circulation deviceCentrifugal fan, long shaft with external motor drive
    Air heating methodNickel-chromium alloy electric heating wire heater
    Heater control method: Contactless equal-cycle pulse width modulation, SSR (solid state relay)
    Heater power: 12kW
    Air cooling methodEvaporator direct cooling
    Refrigeration system
    Way of workingAir-cooled dual refrigeration system
    Refrigeration compressorMechanical compressor
    CondenserFinned Tube Heat Exchanger
    Condensing EvaporatorPlate heat exchanger
    EvaporatorFinned Tube Heat Exchanger
    Throttle deviceElectronic pulse quick-opening cold-end flow cutoff method
    RefrigerantR404a R23 ( The ozone depletion index is 0 in all cases)
    Refrigeration machine control methodThe control system automatically adjusts the chiller operation to the optimal energy-saving condition according to test conditions
    Compressor suction gas cooling circuit
    Evaporation pressure regulating valve
    Condenser fan automatic speed control
    Humidification system
    HumidifierBoiler-type heating and humidification method
    Stainless steel armored heater
    Heater control method: contactless equal-cycle pulse width modulation, SSR (solid-state relay)
    Water level control device, heater dry-burn protection device
    Humidifier power: 3.6 kW
    Humidification system water supply
    Water supply methodPump lift
    Water supply device locationSide water tank (electric suction and automatic water supply)
    Water tank20L
    Water qualityResistivity≥500Ω·m
    Other configurations
    Power cableOne five-core (three-phase four-wire with protective earth) cable (about 5 meters long)
    Specimen power supply control terminal (optional)Relay contact control, within AC240V, 2A (when operating normally, the contacts are closed; when the equipment is stopped or faulty, the contacts are open). Strongly recommend that users use control terminals to control the power on/off of the test sample, to ensure that the power connected to the test sample is reliably cut off when the equipment fails or stops.
    Main power leakage circuit breakerMain power input, leakage circuit breaker and overload circuit breaker
    Rated residual current: 30mA
    Safety device
    Test ChamberAdjustable over-temperature
    Test chamber temperature fuse
    Air regulation channel limit over-temperature
    Fan motor overheating
    Power distribution control cabinet opens power-off protection
    Cabinet door opening (during operation) triggers alarm and multiple openings cause refrigeration system fault alarm protection
    Refrigeration systemCompressor Overheating
    Compressor Overcurrent
    Compressor Overpressure
    Humidification systemHumidification heat pipe overheat protection
    Humidification water shortage abnormal
    Water tank water shortage abnormal
    Electrical control systemMain power phase sequence and phase loss protection
    Main power overvoltage and undervoltage protection
    Leakage protection
    Overload and short circuit protection
    Power Supply
    AC380V/50Hz three-phase four-wire protective grounding
    Voltage range: AC (380±10%) V
    Allowable frequency fluctuation range: (50±0.5) Hz
    Grounding resistance of the protective ground wire should be less than 4Ω
    It is required that the user provides an air switch or power switch of appropriate capacity at the installation site for the equipment, and this switch must be used exclusively for this equipment (recommended power switch capacity: 83A)
    Current45A
    Maximum continuous operating power

    36.5kW

    (Data obtained from the test after running for one hour at an ambient temperature of 25°C, without a sample, under stable operating conditions)

    Quality Multiple Sunlight Simulation Temperature and Humidity Test Chamber QYG-5000 for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: DongGuan Q1-Test Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)